Simple Water Level Detector

It is easy make a simple water level detector circuit. To monitor the filling of a bath, a water-tank, or a swimming pool, or to warn when a gully is overflowing, here’s a very simple water level detector built around a CD4011 CMOS quad NAND chip. Gates IC1.A and IC1.B are wired as an astable multivibrator. The oscillator frequency is determined by C1, R2 and preset P1.

Water Level Detector Circuit Diagram :

Detector-Circuit
When quiescent, resistor R1 pulls the input to gate IC1.A down to logic low, which there-fore by default blocks the operation of the oscillator in the absence of water. When water is present between the e+ an d e−electrodes, IC1. A is taken high, enabling the oscillator. The output signal from gate IC1.B is shaped by IC1.C to obtain a rectangular waveform. Gate IC1.D inverts the signal so that transistor T1 is held of f in the absence of water, which avoids current flowing in the primary of transformer TR1 when the system is at rest. TR1 is a 12 V 1.5 VA AC power transformer wired as a step-up trans-former i.e. with the low-volt age winding connected to T1. The transformer’s step up ratio affords ‘passive’ amplification of the signal present at the drain of T1. The trans-former’s high voltage winding is connected to piezo sounder BZ1 (e.g. Murata; the ‘28’indicates the diameter) which produces the audible warning.

In order to optimise the sound output of the unit, you’ll need to adjust P1 so as to set the oscillator frequency to the resonant frequency of the piezo transducer; this setting can be done by ear. The electronics and batteries can be housed into a salvaged case (for example, the kind of oval box found inside giant chocolate ‘surprise’ eggs). The electrodes, formed from simple rigid copper wires, pass out through the case; the join is made watertight using epoxy adhesive.

Author : André Thiriot  - Copyright : Elektor

Read More

Friday, October 3, 2014

Light Level Droplets Detector Circuit

Here’s a design circuit for Low-Light Level Drop Detector. This circuit utilize self-biasing configuration to detect small changes in light level. This circuit usually used in monitoring very low droplets rates. The collector of the transistor gives feedback that is used to stabilize the bias of the photo darlington. This is the figure of the circuit;
 

The effect on optical performance is reduced by a high base-source impedance that is produced by The 10-μF capacitor and 10-MΩ resistor. When there is a liquid drop is detected by the detector, the light that reach the chip is momentary decreased causing collector voltage to momentarily rise, then output signal is generated. Due to mechanical spacing system constraints and output power constraints on the LED, the initial light bias is small. A fraction of this  initial bias is the change in light level. This fraction is caused by stray light paths and drop translucence. When biased, the output signals level is still acceptable because the photodarlington  has high sensitivity. This compares with unacceptable bias point stability and signal levels when biased conventionally, like signal output across the collector bias resistor and base open. [Circuit diagram source: seekic.com]
Read More

Friday, September 12, 2014

Numeric Water Level Indicator Wiring diagram Schematic

Most water-level indicators for water tanks are based upon the number of LEDs that glow to indicate the corresponding level of water in the container. Here we present a digital version of the water-level indicator. It uses a 7-segment display to show the water level in numeric form from0 to 9. The schema works off 5V regulated power supply. It is built around priority encoder IC 74HC147 (IC1), BCD-to-7-segment decoder IC CD4511 (IC2), 7-segment display LTS543 (DIS1) and a few discrete components. Due to high input impedance, IC1 senses water in the container from its nine input terminals. The inputs are connected to +5V via 560-kilo-ohm resistors.

The ground terminal of the sensor must be kept at the bottom of the container (tank). IC 74HC147 has nine active-low inputs and converts the active input into active-low BCD output. The input L-9 has the highest priority. The outputs of IC1 (A, B, C and D) are fed to IC2 via transistors T1 through T4. This logic inverter is used to convert the active-low output of IC1 into active-high for IC2. The BCD code received by IC2 is shown on 7-segment display LTS543. Resistors R18 through R24 limit the current through the display.

image
When the tank is empty, all the inputs of IC1 remain high. As a result, its output also remains high, making all the inputs of IC2 low. Display LTS543 at this stage shows 0, which means the tank is empty. Similarly, when the water level reaches L-1 position, the display shows 1, and when the water level reaches L-8 position, the display shows 8. Finally, when the tank is full, all the inputs of IC1 become low and its output goes low to make all the inputs of IC2 high. Display LTS543 now shows 9, which means the tank is full. Assemble the schema on a general-purpose PCB and enclose in a box. Mount 7-segment LTS543 on the front panel of the box. For sensors L-1 though L-9 and ground, use corrosion-free conductive-metal (stainless-steel) strips.
Source by : Streampowers
Read More

Monday, August 25, 2014

Sound Level Meter



This is a wonderful schema which gives an attraction for your amp or audio setup so after fixing correctly you will be able to get maximum harvest of it.






Parts List.

Q1 BC 558 PNP Transistor
LED1-LED10 Standard LED or LED Array
R1, R3 1K 1/4W Resistor
R2 10K 1/4W Resistor
R4 100K 1/4W Resistor
R5 1M 1/4W Resistor
D1 1N4001 Silicon Diode
U1 LM3915 Audio Level IC
MISC Board, Wire, Socket For U1
C1 2.2uF 25V Electrolytic Capacitor
C2, C3 0.1uF Ceramic Disc Capacitor